Color Change Lead Screw

bar.bmp

Measurement

  1. The straightness of the color change lead screw cannot exceed 0.010” [0.25mm] at any point of the threaded section.

  2. Measure the straightness by placing a straight edge against the color change screw and measuring the gaps between the straight edge and the screw.

Adjustment

If the flatness of the color change feed screw exceeds 0.010” [0.25mm] it must be replaced following procedures shown in this manual.