Condition |
Solution |
Both LED Cluster Assemblies do not illuminate with the rest of machine having power. |
Troubleshoot the wiring connecting the Main PCB to the LED Cluster assemblies. |
One LED Cluster assembly is completely illuminated but the other one is not. |
Verify the harness connection first. Then replace the non-functional LED cluster assembly. |
Individual LEDs on either LED Cluster Assembly are burned out or fail to illuminate. |
Replace the LED Cluster assembly affected. |