The Status Indicator LED is illuminated when the machine is turned ON.
The LED color and whether it is blinking indicates the machine status or if it has a fault.
Status Light Condition |
Definition |
Action to Take |
Green (blinking) |
Machine is currently booting up |
Start application |
Green (continuous) |
Machine is on and ready for operation |
Load design |
Red (blinking slow) |
Indicates a thread break |
Re-thread the needle with thread break |
Red (blinking fast) |
Indicates the machine has run out of bobbin thread or there has been a bobbin break |
Replace the bobbin or fix the bobbin break |
Green (on for 2 seconds, off for 1/2 second) |
Machine is in low power shutdown (sleep mode) |
Wake Mode – Press the Start key for 3 seconds. To wake all machines in a cluster, press and hold the Start key for 8 seconds. Sleep Mode – Press the Stop key for 3 seconds. To place all machines in a cluster in Sleep Mode, press and hold the Stop key for 8 seconds. |
Red (continuous)
|
Indicates the machine is in E-Stop engaged mode |
Release the red emergency stop button |
Red (continuous) |
Indicates the machine has a sequin head attached and the E-Stop is engaged |
Release the red emergency stop button |