Home Part Replacements What's New FAQs Trouble Shooting Guides Embroidery Tips Support Form Downloads Search Contact Us (links)
| |
| P a r t
R e p l a c e m e n t I n s t r u c t i o n |
Product: EMC 6M, EMC 6ML, EMC 6MTL, EMC 6/4M, EMC 6/4MT
Parts Replaced: Needle Bar
Required Tools:
 | Small Slotted Screw Driver
 | 4mm Allen Wrench
 | 2.5mm Allen Wrench |
| |
Procedure:
- Turn the peripheral off and unplug the Power Cord.
- Unthread the Peripheral.
- Remove the two Socket Head Cap Screws and washers holding the
Tensioner Assembly (See Figure 1-A) to the Needle Case (See Figure 1-B).
Figure 1
- Slightly lift the Tensioner Assembly and unplug the flat blue Ribbon
Cable. Place the Tensioner Assembly aside.
- Remove the Needle Case Cover by unsnapping it from the Needle Case
Assembly. Snap area indicated by the dashed lines. (See Figure 1-C)
Figure 2
- Loosen the Needle Clamp Set Screw (See Figure 2-D) and remove the
Needle from the Needle Bar to be changed.
- Continue to loosen the Needle Clamp Set Screw enough to remove the
Needle Clamp (See Figure 2-E) from the Needle Bar.
- Loosen the Needle Bar Driver Set Screw (See Figure 2-F).
NOTE: Be sure to hold on to the Needle Bar when performing the
next step, since it will release tension on the Needle Bar Spring.
- Loosen the Upper Dead Stop Clamp Set Screw (See Figure 2-G).
NOTE: When removing the Needle Bar, take care not to drop or lose
the components being held in place by the bar.
- Slide the Needle Bar out of the top of the Needle Case. As the Needle
Bar slides out, lay the following components aside for use when
re-assembling:
- Lower "O" Ring (See Figure 2-H)
- Upper "O" Ring (See Figure 2-I)
- Presser Foot (See Figure 2-J)
- Lower Needle Bar Spring (See Figure 2-K)
- Needle Bar Driver (See Figure 2-F)
- Upper Dead Stop Clamp (See Figure 2-G)
- Upper Needle Bar Spring (See Figure 2-L)
- Lightly oil the new Needle Bar.
- Slide the Needle Bar into the Needle Case, making sure to replace all
of the components removed in step 10.
- Replace the Needle Clamp (from step 7), but do not install the needle
yet.
- Rotate the Needle Bar so that the Needle Clamp Set Screw points at a
45° angle to the right.
- Hold the top of the Needle Bar level with the rest of the Needle Bars
in the Needle Case, slide the Needle Bar Driver to where it is even with
the rest, and tighten the Needle Bar Driver Set Screw.
- Install the Needle.
- Plug in the Power Cord and turn the peripheral on.
- After the peripheral downloads, move the Needle Case to the Needle Bar
just changed.
- Using the "H E A D TIMING MENU" functions, go to Head-Up,
One Revolution, then to Needle Depth.
- Slightly loosen the Needle Bar Driver Set Screw and set Needle Depth.
- Using the "H E A D TIMING MENU" functions, go to Hook
Timing, then press the [RIGHT ARROW] key nine times.
- Slide the Upper Dead Stop Clamp up until it is firmly against the
black Rubber Stop at the top of the Needle Case and tighten the Set
Screw.
- Using the "H E A D TIMING MENU" functions, go to Head-Up.
- Turn the peripheral off.
- Plug the blue Ribbon Cable back into the connector on the bottom of
the Tensioner Assembly.
- Replace the Tensioner Assembly on the Needle Case, using the Socket
Head Cap Screws and washers removed in step 3.
- Replace the Needle Case Cover.
- Re-thread the peripheral.
- Perform a sew out test.
|