B a s i c   M a i n t e n a n c e   F o r   M e l c o   S e w i n g   P e r i p h e r a l s

2. Lubrication

 

Upper Connecting Rod

EMC 1, ADV 18:

To lubricate the upper connecting rod from the front, follow these steps and refer to Figure 2-11.

Figure 2-11

  1. Slide the front cover of the needle case to one side to access the needle bar driver area.
  2. Press the [MENU] key until the LCD displays: HEAD TIMING MENU.
  3. Press the [ALT][Ý]keys.
  4. Press the [ALT][ß]keys.
  5. Press the [Þ]key. This will place the upper lubrication hole of the connecting rod directly behind the slot in the plastic guide. It is located just to the right of the needle bar driver.
  6. Put 1-3 drops of sewing machine oil in the upper lubrication hole every 80 operating hours.

EMC 6, EMC 6/4:

There is no lubrication hole on the connecting rod for the EMC 6 series.

EMC 6M, EMC 6ML, EMC 6MLT, EMC 6/4M, EMC 6/4MT:

The following steps and Figure 2-12 describe how to lubricate the upper connecting rod.

Figure 2-12

  1. Move the needle case all the way to the right (needle #6 position).
  2. Press the [MENU] key until the LCD displays: HEAD TIMING MENU.
  3. Press the [ALT][Ý] keys.
  4. Press the [ALT][ß] keys.
  5. Press the [Þ] key. This will place the upper lubrication hole of the connecting rod approximately 2 inches (5 cm) below the access hole located on top of the arm casting, just behind the needle case and left of center, as shown in Figure 2-12.
  6. Position an oiler tube thru the access hole and place the tip of the tube over the upper lubrication hole. Put 1 to 3 drops of sewing machine oil into the hole every 80 operating hours.

EMC 10, EMC 10T, EMC 10/4, EMC 10/4T:

The upper connecting rod is accessed near the lower right side of the needle case, follow these steps and refer to Figure 2-13.

,B>Figure 2-13

  1. Move the needle case to position #1.
  2. To the right of the needle case, locate the front arm cover and loosen both screws.
  3. Swing the cover down and to the right.
  4. Press the [MENU] key until the LCD displays: HEAD TIMING MENU.
  5. Press the [ENTER] key. The LCD displays: HEAD TIMING ON.
  6. Press the [ALT][Ý] keys one time. The LCD displays: GO TO HEADUP
  7. Press the [ALT][ß] keys. The LCD displays: NEEDLE DEPTH. Now you can see the connecting rod as shown in Figure 2-13.
  8. Put 1 to 3 drops of sewing machine oil in the hole at the top of the connecting rod. Do this every 80 operating hours.
  9. Replace the front arm cover securely.

 

 